• Simultaneous Power & Power quality measurements
• Helpful support functions
• Measurement with high accuracy
• Remote monitoring on PC and Android device
• Various Clamp Current Sensors
• Energy consumption check on site
• IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V

GET QUOTE


Specifications

  • KEW Smart 6315

  • Please search "KEW Smart" in Google Play Store.Communication charge may be incurred separately to download application.

  • Range

    8128/8135 ( 50A type ) : 5000mA / 50.00A / AUTO8127 ( 100A type ) : 10.00 / 100.0A / AUTO8126 ( 200A type ) : 20.00 / 200.0A / AUTO8125 ( 500A type ) : 50.00 / 500.0A / AUTO8124/8130 ( 1000A type ) : 100.0 / 1000A / AUTO8146/8147/8148 ( 10A type ) : 1000mA / 10.00A / AUTO8133 ( 3000A type ) : 300.0 / 3000A / auto

  • Display

    320 × 240 (RGB) Pixel, 3.5inch color TFT display

  • Accuracy

    ±0.2%rdg±0.2%f.s. + accuracy of clamp sensor (sine wave, 40 - 70Hz)

  • Accuracy

    ±0.3%rdg±0.2%f.s. + accuracy of clamp sensor(power factor 1, sine wave, 40 - 70Hz)

  • Active power

  • Crest factor

    3 or less

  • Current (RMS)

  • Display range

    0.15 - 130% of each range

  • Voltage (RMS)

  • Allowable input

    1 - 110% of each range (rms). 200% of each range (peak)

  • Internal memory

    FLASH memory (4MB)

  • PC card interface

    SD card (2GB)

  • Wiring connections

    1P2W, 1P3W, 3P3W, 3P4W

  • Display update period

    1 sec

  • Frequency meter range

    40 - 70Hz

  • Power supply (AC Line)

    AC100 - 240V / 50 - 60Hz / 7VA max

  • Influence of power factor

    ±1.0%rdg (reading at power factor 0.5 against power factor 1)

  • Power supply (DC battery)

    Alcaline size AA battery LR6 or Ni-MH (HR-15-51) × 6Battery life approx. 3h (LR6, Backlight OFF)

  • PC communication interface

    USB Ver2.0, Bluetooth Ver2.1 + EDR Class2

  • Measurements and parameters

    Voltage, Current, Frequency, Active power, Reactive power, Apparent power,Active energy, Reactive energy, Apparent energy, Power factor (cos θ),Neutral current, Demand, Harmonics, Quality (Swell/Dip/Interruption, Transients/Over voltage, Inrush current, Unbalance rate),Capacitance calculation for PF correction unit, Flicker

  • Sampling speed of Voltage transient

    24µs

  • Weight

    Approx. 900g

  • Dimension

    175(L) × 120(W) × 68(D) mm

  • Applicable standards

    IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V Pollution degree 2 IEC 61010-2-030, IEC 61010-031, IEC 61326, EN 50160 IEC 61000-4-30 Class S, IEC 61000-4-15, IEC 61000-4-7

  • Included Accessories

    7141B (Voltage test lead) 7170 (Power cord) 7219 (USB cable) 8326-02 (SD card 2GB) 9125 (Carrying case for KEW 6315, KEW 6315-01) 9135 (Carrying case for KEW 6315-03, KEW 6315-04, KEW 6315-05) Input terminal plate × 6, KEW Windows for KEW 6315 (PC software), Quick manual, Alkaline size AA battery (LR6) × 6

  • Optional Accessories

    8124/8125/8126/8127/8128 (Load current clamp sensor) 8130/8133(*)/8135(*) (Flexible clamp sensor) 8146/8147/8148 (Leakage and Load current clamp sensor) 8312 (Power supply adaptor) 9132 (Magnet carrying case)

  • Power supply (AC Line)

    AC100 - 240V / 50 - 60Hz / 7VA max

  • Power supply (DC battery)

    Alcaline size AA battery LR6 or Ni-MH (HR-15-51) × 6 Battery life approx. 3h (LR6, Backlight OFF)

  • Temperature and humidity range

    23±5ºC, less than 85% RH (without condensation)

  • Storage temperature & humidity range

    -20 - +60ºC, less than 85% RH (without condensation)

  • Operating temperature & humidity range

    0 - +45ºC, less than 85% RH (without condensation)