Kyoritsu KEW 6315 POWER QUALITY ANALYZER
Brand :
Kyoritsu
Categories :
Loggers-Power Meters-PQA
• Simultaneous Power & Power quality measurements
• Helpful support functions
• Measurement with high accuracy
• Remote monitoring on PC and Android device
• Various Clamp Current Sensors
• Energy consumption check on site
• IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V
Specifications
-
KEW Smart 6315
-
Please search "KEW Smart" in Google Play Store.Communication charge may be incurred separately to download application.
-
Range
8128/8135 ( 50A type ) : 5000mA / 50.00A / AUTO8127 ( 100A type ) : 10.00 / 100.0A / AUTO8126 ( 200A type ) : 20.00 / 200.0A / AUTO8125 ( 500A type ) : 50.00 / 500.0A / AUTO8124/8130 ( 1000A type ) : 100.0 / 1000A / AUTO8146/8147/8148 ( 10A type ) : 1000mA / 10.00A / AUTO8133 ( 3000A type ) : 300.0 / 3000A / auto
-
Display
320 × 240 (RGB) Pixel, 3.5inch color TFT display
-
Accuracy
±0.2%rdg±0.2%f.s. + accuracy of clamp sensor (sine wave, 40 - 70Hz)
-
Accuracy
±0.3%rdg±0.2%f.s. + accuracy of clamp sensor(power factor 1, sine wave, 40 - 70Hz)
-
Active power
-
Crest factor
3 or less
-
Current (RMS)
-
Display range
0.15 - 130% of each range
-
Voltage (RMS)
-
Allowable input
1 - 110% of each range (rms). 200% of each range (peak)
-
Internal memory
FLASH memory (4MB)
-
PC card interface
SD card (2GB)
-
Wiring connections
1P2W, 1P3W, 3P3W, 3P4W
-
Display update period
1 sec
-
Frequency meter range
40 - 70Hz
-
Power supply (AC Line)
AC100 - 240V / 50 - 60Hz / 7VA max
-
Influence of power factor
±1.0%rdg (reading at power factor 0.5 against power factor 1)
-
Power supply (DC battery)
Alcaline size AA battery LR6 or Ni-MH (HR-15-51) × 6Battery life approx. 3h (LR6, Backlight OFF)
-
PC communication interface
USB Ver2.0, Bluetooth Ver2.1 + EDR Class2
-
Measurements and parameters
Voltage, Current, Frequency, Active power, Reactive power, Apparent power,Active energy, Reactive energy, Apparent energy, Power factor (cos θ),Neutral current, Demand, Harmonics, Quality (Swell/Dip/Interruption, Transients/Over voltage, Inrush current, Unbalance rate),Capacitance calculation for PF correction unit, Flicker
-
Sampling speed of Voltage transient
24µs
-
Weight
Approx. 900g
-
Dimension
175(L) × 120(W) × 68(D) mm
-
Applicable standards
IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V Pollution degree 2 IEC 61010-2-030, IEC 61010-031, IEC 61326, EN 50160 IEC 61000-4-30 Class S, IEC 61000-4-15, IEC 61000-4-7
-
Included Accessories
7141B (Voltage test lead) 7170 (Power cord) 7219 (USB cable) 8326-02 (SD card 2GB) 9125 (Carrying case for KEW 6315, KEW 6315-01) 9135 (Carrying case for KEW 6315-03, KEW 6315-04, KEW 6315-05) Input terminal plate × 6, KEW Windows for KEW 6315 (PC software), Quick manual, Alkaline size AA battery (LR6) × 6
-
Optional Accessories
8124/8125/8126/8127/8128 (Load current clamp sensor) 8130/8133(*)/8135(*) (Flexible clamp sensor) 8146/8147/8148 (Leakage and Load current clamp sensor) 8312 (Power supply adaptor) 9132 (Magnet carrying case)
-
Power supply (AC Line)
AC100 - 240V / 50 - 60Hz / 7VA max
-
Power supply (DC battery)
Alcaline size AA battery LR6 or Ni-MH (HR-15-51) × 6 Battery life approx. 3h (LR6, Backlight OFF)
-
Temperature and humidity range
23±5ºC, less than 85% RH (without condensation)
-
Storage temperature & humidity range
-20 - +60ºC, less than 85% RH (without condensation)
-
Operating temperature & humidity range
0 - +45ºC, less than 85% RH (without condensation)