FLIR X8580™ High Definition MWIR Science-Grade Camera
Brand :
Teledyne FLIR
Categories :
High Performance Cameras
The FLIR X8580 midwave IR camera is designed for scientists and engineers who need to capture detailed imagery of high-speed events, perform custom radiometric measurements, or detect points of failure in composites, solar cells, and electronics. This thermal imaging camera combines 1280 × 1024 HD resolution with fast frame rates and integration times, allowing researchers to record stop motion on fast-moving subjects or rapid temperature changes—whether in the lab or on the test range. With a four-position motorized filter wheel and support for FLIR motorized focus lenses, the X8580 will provide higher quality recordings, save time, and mitigate frustration in dynamic acquisition environments.
Multiple Software Interfaces
Stream thermal data directly from the SSD over any of the digital data buses for advanced analysis with FLIR Research Studio software
Synchronization and Triggering
Capture essential data easily and control image frame generation precisely with dedicated trigger input and new Tri-level Sync input
On-Camera RAM and SSD Recording
Record up to 34 seconds of full HD resolution data directly to on-camera memory, or up to 15 minutes to included 512 GB SSD
Specifications
-
NETD
30 mK typical
-
Focus
Motorized (compatible w/manual)
-
Filtering
4-Position motorized warm filter wheel, standard 1-inch filters, user swappable
-
Resolution
1280 × 1024
-
Detector Type
FLIR indium antimonide (InSb)
-
Dynamic Range
14-bit
-
Detector Pitch
12 µm
-
Spectral Range
1.5–5.0 µm
-
Camera f-number
f/2.5
-
Frame Rate [Full Window]
Programmable: ~0.5 Hz to 181 Hz
-
Optional Temperature Range [with band matched optics]
ND1: 45°C–600°C (113°F–1112°F) ND2: 250°C–2000°C (482°F–3632°F) ND3: 500°C–3000°C (957°F–5432°F)
-
Standard Temperature Range [with band matched optics]
-20°C to 350°C (-4°F to 662°F)
-
NETD
30 mK typical
-
Focus
Motorized (compatible w/manual)
-
Overlay
Customizable (ability to toggle off)
-
Palette
Selectable 8-bit
-
Filtering
4-Position motorized warm filter wheel, standard 1-inch filters, user swappable
-
Resolution
1280 × 1024
-
Operability
≥99.95% typical
-
Pixel Clock
355 MHz
-
Video Modes
HD-SDI: 720p@50/59.9Hz, 1080p@25/29.97Hz; SD-SDI: 480i@60Hz, 576i@50Hz
-
Digital Zoom
1x, Auto (best fit)
-
Readout Type
Snapshot
-
Detector Type
FLIR indium antimonide (InSb)
-
Dynamic Range
14-bit
-
Readout Modes
Asynchronous integrate while read, Asynchronous integrate then read
-
Detector Pitch
12 µm
-
Lens Interface
FLIR FPO-M (4-tab bayonet, motorized)
-
Sensor Cooling
Linear sterling cooler
-
Spectral Range
1.5–5.0 µm
-
Standard Video
HDMI, SDI
-
Camera f-number
f/2.5
-
Subwindow Modes
Flexible windowing down to 64 × 4 (steps of 64 columns, 4 rows)
-
Available Lenses
Manual (broadband): 25 mm, 50 mm, 100 mm Motorized (broadband): None
-
Image Time Stamp
Internal IRIG-B decoder clock TSPI accurate time stamp
-
Direct to SSD Recording
Yes, removable 512 GB SSD included
-
On Camera Image Storage
RAM (volatile): 16 GB, up to 6,500 frames full frame SSD (user-removable/non-volatile): ~15 minutes of recording with included 512 GB SSD (more than 2 hours possible with 4 TB SSD purchased separately)
-
Frame Rate [Full Window]
Programmable: ~0.5 Hz to 181 Hz
-
Radiometric Data Streaming
Simultaneous Gigabit Ethernet (GigE Vision), Camera Link,CoaXPress® 1.1, dual 5 Gb links
-
Close-up Lenses/Microscopes
No broadband microscopes available
-
Accuracy
≤100°C: ±2°C (±1°C typical), >100°C: ±2% of reading (±1% typical)
-
Automatic Gain Control
Manual, Linear, Plateau equalization, ROI, DDE
-
Ambient Drift Compensation [with factory cal]
Yes
-
Optional Temperature Range [with band matched optics]
ND1: 45°C–600°C (113°F–1112°F) ND2: 250°C–2000°C (482°F–3632°F) ND3: 500°C–3000°C (957°F–5432°F)
-
Standard Temperature Range [with band matched optics]
-20°C to 350°C (-4°F to 662°F)
-
Synchronization Modes
Sync In, Sync Out, Tri-Level Sync
-
Power
24 VDC (<50 W steady state)
-
Mounting
2 × 1/4 in -20 / 1 × 3/8 in -16 / 4 × #10 -24 / Side: 3x 1/4 in -20 (each side)
-
Operating Temperature Range