Find potential design flaws, assess hot spots, and gather accurate thermal data with the high-resolution FLIR T560. This 640 × 480 (307,200 pixel) uncooled thermal camera produces crisp, vibrant imagery that can be enhanced through UltraMax® technology for up to 1.2 MP thermal resolution. Measure components down to 50 µm/pixel spot size with the optional Macro Mode or down to 24 µm/pixel with a 2x macro lens. Thanks to the award-winning ergonomic design and intuitive, rapid-response interface, the T560 can increase efficiency and help reduce test times. When coupled with Research Studio software, these cameras help researchers perform in-depth analysis and share data quickly.

GET QUOTE

Intuitive Thermal Imagery

Build client trust through sharply-focused, brilliant images that are also easy for non-experts to interpret.

Efficient Testing and Reporting

Set up and start testing quickly with the intuitive graphic user interface and streamlined user features and analysis tools.

Precise Temperature Measurement

The T560 offers the temperature sensitivity needed to detect differences smaller than 0.03°C and the measurement range to quantify heat generation up to 1500°C.


Specifications

  • Focus

    Continuous with laser distance meter (LDM), one- shot LDM, one-shot contrast, manual

  • f-number

    1.5

  • Resolution

    640 × 480

  • Spectral Range

    7.5 - 14 µm

  • Frame Rate [Full Window]

    30 Hz

  • Thermal Sensitivity/NETD

    <50 mK @ 30°C (86°F)

  • Lens

    14°

  • Color

    Black

  • Focus

    Continuous with laser distance meter (LDM), one- shot LDM, one-shot contrast, manual

  • Gallery

    Yes

  • UltraMax

    Quadruples pixel count; activated in menu and processed in FLIR Tools

  • f-number

    1.5

  • Resolution

    640 × 480

  • Video Lamp

    Built-in LED light

  • Viewfinder

    No

  • Digital Zoom

    1–8× continuous

  • Focal Length

    29 mm (1.41 in)

  • Visual Image

    Yes

  • Field of View

    14° × 10°

  • Color Palettes

    Iron, Gray, Rainbow, Arctic, Lava, Rainbow HC

  • Digital Camera

    5 MP, with built-in LED photo/video lamp

  • Spectral Range

    7.5 - 14 µm

  • Image Frequency

    30 Hz

  • Laser Alignment

    Position is automatically displayed on the infrared image

  • Digital Camera FOV

    53° × 41°

  • Picture-in-Picture

    Resizable and movable

  • Lens Identification

    Automatic

  • Camera software update

    Using USB cable or SD card

  • Minimum Focus Distance

    1.0 m (3.28 ft)

  • Visual Video Recording

    H.264 to memory card

  • Visual Video Streaming

    Yes

  • Detector Type and Pitch

    Uncooled microbolometer, 12 µm

  • Frame Rate [Full Window]

    30 Hz

  • Thermal Sensitivity/NETD

    <50 mK @ 30°C (86°F)

  • Spatial resolution (IFOV)

    0. 4 mrad/pixel

  • Radiometric IR video recording

    Real-time radiometric recording (.csq)

  • Radiometric IR video streaming

    Over UVC

  • Minimum Focus Distance with MSX

    1.0 m (3.28 ft)

  • Non-radiometric IR video streaming

    H.264 or MPEG-4 over Wi-Fi MJPEG over UVC or Wi-Fi

  • Accuracy

    ±2°C (±3.6°F) or ±2% of reading

  • Measurement Presets

    No measurements, center spot, hot spot, cold spot. User Preset 1, User Preset 2

  • Emissivity Correction

    Yes, variable from 0.01 to 1.0 or selected from materials list

  • Reference Temperature

    Yes

  • Color Alarm (Isotherm)

    Above, Below, Interval, Condensation (moisture/humidity/dewpoint), Insulation

  • Difference Temperature

    Yes

  • Measurement Corrections

    Yes

  • Object Temperature Range

    -20°C to 120°C (-4°F to 248°F); 0°C to 650°C (32°F to 1202°F); 300°C to 1500°C (572°F to 2732°F)

  • Measurement Function Alarm

    Audible/visual alarms (above/below) on any selected measurement function

  • Automatic hot & cold detection

    Automatic maximum/minimum markers within area

  • USB

    USB Type-C: data transfer/video/power

  • Audio

    Microphone and speaker for voice annotation of images

  • METERLiNK

    Wireless connection (Bluetooth®) to: FLIR meters with METERLiNK

  • Video Out

    DisplayPort over USB Type-C

  • Storage Media

    Removable SD card

  • USB - Standard

    USB 2.0 High Speed

  • Image File Format

    Standard JPEG with measurement data included

  • METERLiNK - Bluetooth

    Communication with headset and external sensors

  • Communication Interfaces

    USB 2.0, Bluetooth®, Wi-Fi

  • Packaging

    Infrared camera with lens, 2 batteries, battery charger, hard transport case, lanyards, front lens cap, power supplies, printed documentation, SD card (8 GB), cables (USB 2.0 A to USB Type-C, USB Type-C to HDMI, USB Type-C to USB Type-C)

  • Laser Pointer

    Class 2, 0.05–40 m (0.16–131 ft) ±1% of measured distance

  • Packaging Size

    500 × 190 × 370 mm (19.7 × 7.5 × 14.6 in)

  • Housing material

    PCABS with TPE, magnesium

  • Size (L x W x H)

    Lens horizontal: 140 × 201.3 × 167.3 mm (5.5 × 7.9 × 6.6 in)

  • Weight [battery included]

    1.4 kg (3.1 lb)

  • Voice

    60 sec. recording added to still images or video via built-in mic (has speaker) or via Bluetooth®

  • Display

    4", 640 × 480 pixel touchscreen LCD with auto-rotation

  • Languages

    21

  • Touch Screen

    Optically bonded PCAP

  • Display Technology

    IPS

  • Battery type

    Li-ion battery, charged in camera or on separate charger

  • Battery weight

    195 g (6.89 oz)

  • Battery voltage

    3.6 V

  • Charging system

    In camera (AC adapter or 12 V from a vehicle) or two-bay charger

  • Power Management

    Automatic shut-down and sleep mode

  • Charging Temperature

    0°C to 45°C (32°F to 113°F)

  • Battery operating time

    Approx. 4 hours at 25°C (77°F) ambient temperature and typical use

  • External Power Operation

    AC adapter 90–260 V AC (50/60 Hz) or 12 V from a vehicle (cable with standard plug, optional)

  • EMC

    ETSI EN 301 489-1 (radio), ETSI EN 301 489-17, EN 61000-6-2 (immunity), EN 61000-6-3 (emission), FCC 47 CFR Part 15 Class B (emission)

  • Safety

    EN/UL/CSA/PSE 60950-1

  • Warranty

    http://www.flir.com/warranty/

  • Radio Spectrum

    ETSI EN 300 228, FCC Part 15.249, RSS-247 Issue 2

  • Tripod Mounting

    UNC 1/4"-20

  • Storage Temperature Range

    -40°C to 70°C (-40°F to 158°F)

  • Operating Temperature Range

    -15°C to 50°C (5°F to 122°F)

  • Humidity (Operating and Storage)

    IEC 60068-2-30/24 hours, 95% relative humidity, 25–40°C (77–104°F)/2 cycles