FLIR GF77a Fixed Gas Find IR Camera
Brand :
Teledyne FLIR
Categories :
Fixed Thermal Cameras
, Lense
, Optical Gas Imaging
, Gas Detection Cameras
The FLIR GF77a is the first uncooled autonomous leak detection camera from FLIR designed specifically to visualize methane gas. This affordable, fixed-camera solution provides upstream and midstream gas processors, producers, or operators the features they need to continuously monitor for potentially dangerous, invisible methane leaks. Small and lightweight, the FLIR GF77a is packed with FLIR-patented features, such as High Sensitivity Mode (HSM), for improved gas visualization. The GF77a can help oil and gas companies maintain valuable capital equipment, avoid product loss, meet emissions reduction metrics, and ensure safer work practices. The GF77a also comes in a GF77f variant that includes environmental housing for harsh environments.
UNMATCHED CONNECTIVITY
RTSP and GigE compliant, the GF77a offers flexibility to meet many industrial communication needs and connects to a network for continuous leak detection.
VISUALIZE INDUSTRIAL GASES
Spectrally-filtered to detect methane gases, improving worker safety and leak location identification with fewer in-person inspections.
AFFORDABLE FIXED OGI SOLUTION
Offers industry-leading features for continuous monitoring applications including High Sensitivity Mode, remote motorized focus, and open architecture for third-party integration.
Specifications
-
WiFi
Wi-Fi standard – IEEE802.11a/b/g/n
-
Accuracy
Range 1: -20° to 80°C (-4° to 176°F) ±3°C (±5°F), Range 2: 0° to 250°C (212° to 482°F): 0° to 100°C (32° to 212°F):±3°C, 100° to 250°C (212° to 482°F):±3%, Range 3: 100° to 500°C (212° to 932°F):±3%
-
Encoding
Video streaming – RTSP Protocol: H.264 / MPEG4 / MJPEG; GVSP: Uncompressed Radiometric streaming – RTSP Protocol: Compressed JPEG-LS, FLIR radiometric; GVSP: Uncompressed, signal linear, temperature linear, FLIR radiometric
-
Digital Inputs
2x opto-isolated, Vin (low) = 0 - 1.5 V, Vin (high) = 3-25V
-
Digital Outputs
3x opto-isolated, 0–48 VDC, max. 350 mA (derated to 200 mA at 60. Solid-state opto relay, 1x dedicated as Fault output (NC)
-
Image Frequency
30 Hz
-
Digital Output Purpose
• Programmatically set • Fault (NC)
-
Thermal Resolution [NETD]
<25 mk at 30°C (86°F)
-
Digital I/O connector type
M12 Male 12-pin A-coded (shared with ext. power)
-
WiFi
Wi-Fi standard – IEEE802.11a/b/g/n
-
Unicast
RTSP Protocol, GVSP (GigE Vision) Protocol
-
Encoding
Video streaming – RTSP Protocol: H.264 / MPEG4 / MJPEG; GVSP: Uncompressed Radiometric streaming – RTSP Protocol: Compressed JPEG-LS, FLIR radiometric; GVSP: Uncompressed, signal linear, temperature linear, FLIR radiometric
-
Connector
Pan and tilt control: M8 A-coded, male; Wi-Fi: Female RP-SMA (Pan/Tilt is an optional feature)
-
Multicast
RTSP Protocol, GVSP (GigE Vision) Protocol
-
Digital Inputs
2x opto-isolated, Vin (low) = 0 - 1.5 V, Vin (high) = 3-25V
-
Ethernet Power
Power over Ethernet, PoE IEEE 802.3af class 3
-
Connection Type
Wi-Fi: Peer to peer (ad hoc) or infrastructure (network)
-
Digital Outputs
3x opto-isolated, 0–48 VDC, max. 350 mA (derated to 200 mA at 60. Solid-state opto relay, 1x dedicated as Fault output (NC)
-
Ethernet Protocols
IEEE 1588, SNMP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, sftp (server), FTP (client) SMTP, DHCP, MDNS (Bonjour), uPnP
-
Serial Communication
Pan and tilt control: RS232 and RS485 exclusively
-
Digital Output Purpose
• Programmatically set • Fault (NC)
-
Ethernet Communication
GigE Vision ver. 1.2, Client API GenICam compliant, TCP/IP socket-based FLIR proprietary
-
Ethernet Connector Type
M12 8-pin X-coded, Female
-
Ethernet Image Streaming
Yes
-
Digital I/O connector type
M12 Male 12-pin A-coded (shared with ext. power)
-
Focus
One-shot contrast, motorized, manual
-
Overlay
Image Source 0: RTSP Protocol: with, without; GVSP (GigE Vision) Protocol, with, without,
-
Video Lamp
Built-in LED light
-
Focal Length
25° lens: 18 mm 6° lens: 74 mm
-
Detector Type
Uncooled microbolometer
-
IR Resolution
320 × 240 (76,800) pixels
-
Detector Pitch
25 µm
-
Spectral Range
7 – 8.5 µm
-
Image Frequency
30 Hz
-
Visual Resolution
1280 × 960 pixels
-
Field of view (FOV)
25° lens: 25° × 19° 6° lens: 6.4° × 4.9°
-
Contrast Enhancement
Histogram equalization (IR only) for RTSP and GVSP video streaming, Image Source 0
-
FLIR Screen-EST Mode
No
-
Visual Focus and FOV
Fixed, 67.2° diagonal
-
Gas Sensitivity [NECL]
CH4 (<100 ppm × m), N2O (<75 ppm × m), C3H8 (<400 ppm × m), SO2 (<30 ppm x m); ΔT = 10°C, distance = 1 m
-
Minimum Focus Distance
0.3 m (0.98 ft) for 25° lens; 5 m (16.4 ft) for 6° lens
-
Spatial resolution (IFOV)
1.4 mrad/pixel
-
Thermal Resolution [NETD]
<25 mk at 30°C (86°F)
-
Focal Plane Array (FPA) - Spectral range
Uncooled microbolometer/7 – 8.5 µm
-
Accuracy
Range 1: -20° to 80°C (-4° to 176°F) ±3°C (±5°F), Range 2: 0° to 250°C (212° to 482°F): 0° to 100°C (32° to 212°F):±3°C, 100° to 250°C (212° to 482°F):±3%, Range 3: 100° to 500°C (212° to 932°F):±3%
-
Correction Options
Atmospheric, optics transmission, emissivity, reflected apparent temperature, external optics/window
-
Measurement Corrections
Global object parameters
-
Object Temperature Range
Range 1: -20° to 80°C (-4° to 176°F), Range 2: 0° to 250°C (212° to 482°F), Range 3: 100° to 500°C (212° to 932°F)
-
Weight
0.82 kg (1.8 lbs)
-
Pan/Tilt
Optional feature; Control standard – Pelco D
-
Size [L × W × H]
123 × 77 × 77 mm (4.84 × 3.03 × 3.03 in)
-
Encapsulation
IP 54 (IEC 60529) IP66 with accessory
-
General
PoE or external
-
External Voltage
Allowed range 18-56 VDC, 8 W max
-
Power Consumption
6.8 W at 24 V DC typical 7.0 W at 48 V DC typical 7.3 W at 48 V PoE typical
-
Web interface
Yes