Home/Brands/ Teledyne FLIR/Optical Gas Imaging

FLIR G306 Optical Gas Imaging (OGI) Camera for Sulfur Hexafluoride (SF₆)

Brand : Teledyne FLIR
Categories : Optical Gas Imaging , Gas Detection Cameras

The FLIR G306 is an innovative Optical Gas Imaging (OGI) camera used to visualize sulfur hexafluoride (SF₆), ammonia (NH), ethylene (C₂H₄), and other industrial gas leaks in various environments. SF₆ is a potent greenhouse gas with a global warming potential that’s more than 23,000 times greater than C0₂ over a 100-year period. SF₆ is commonly used within the electric power industry as an insulator and quenching medium for gas-insulated substations and circuit breakers. With the portable, non-contact G306, you can safely and efficiently scan substations for dangerous and environmentally harmful gas leaks without interfering with electric utility delivery or shutting down industrial operations.

GET QUOTE

Superior Gas Visualization

The FLIR G306 accurately measures temperatures from -40°C to 500°C (-40°F to 932°F) and FLIR’s patented High-Sensitivity Mode (HSM) makes (SF₆) and other industrial gas leaks stand out more clearly while allowing you to efficiently scan thousands of components

Improved software integration

Built-in Wi-Fi and Bluetooth® allow you to connect to smartphones or tablets and effortlessly edit and store images in the cloud, or wirelessly transfer files using the included FLIR Ignite™ cloud service

Ergonomic for comfortable operation

Comfortably operate and interact with your G306 thanks to a rotating 10.16 cm (4 in) LCD touchscreen, which allows you view targets from any direction


Specifications

  • Accuracy

    ±1°C (±1.8°F) for temperature range (0°C to 100°C, 32°F to 212°F) or ±2% of reading for temperature range (>100°C, >212°F)

  • IR Resolution

    320 × 240 pixels (76,800 pixels)

  • Detector Pitch

    30 µm

  • Spectral Range

    10.3 µm to 10.7 µm

  • Zoom

    1-8x continuous, digital zoom

  • Focus

    Manual or Automatic

  • Color LCD

    4", 640 × 480 pixel rotatable, touchscreen LCD

  • Laser Spot

    Yes

  • Image Modes

    IR image, visual image, High Sensitivity Mode (HSM)

  • Visual Image

    3.2 MP from integrated visible camera

  • Detector Type

    Focal plane array, cooled QWIP

  • Field of View

    14.5° × 10.8°

  • IR Resolution

    320 × 240 pixels (76,800 pixels)

  • Color Palettes

    Iron, Gray, Rainbow, Arctic, Lava, Rainbow HC

  • Detector Pitch

    30 µm

  • Image Analysis

    10 spots, 5 boxes with max/min/average, 1 line (horizontal or vertical), measurement corrections

  • Sensor Cooling

    Stirling Microcooler (FLIR MC-3)

  • Spectral Range

    10.3 µm to 10.7 µm

  • Camera f-number

    1.59

  • Radiometric JPG

    Yes

  • Display Frame Rate

    60 Hz

  • MPEG Video Recording

    Yes

  • Radiometric IR Video

    RTRR (.csq), Over UVC

  • Adjustable Viewfinder

    Built-in, tiltable OLED, 800 × 480 pixels

  • Video Recording & Streaming

    Real-time non-radiometric streaming: RTP/MPEG4

  • Delta T

    Yes

  • Profile

    1 live line (horiz. or vert.)

  • Accuracy

    ±1°C (±1.8°F) for temperature range (0°C to 100°C, 32°F to 212°F) or ±2% of reading for temperature range (>100°C, >212°F)

  • Area Box

    5 (min./max./avg.)

  • Recording

    MultiREC Recording; Record multiple files automatically in customizable order

  • Spot Meter

    10

  • Gas Sensitivity

    SF₆: <0.3 ppm x m (ΔT = 10°C, Distance = 1 m)

  • Temperature Range

    -40°C to 500°C (-40°F to 932°F) Available sub ranges: -40°C to 50°C (-40°F to 122°F) -20°C to 120°C (-4°F to 248°F) 80°C to 250°C (176°F to 482°F) 150°C to 350°C (302°F to 662°F) 250°C to 500°C (482°F to 932°F)

  • Thermal Sensitivity

    <15 mK @ 30°C (86°F)

  • Measurement Corrections

    Reflected temperature, distance, atmospheric transmission, humidity, external optics

  • Radio

    Operating frequency: •Bluetooth + EDR: 2402–2480 MHz •WLAN 2.4 GHz: 2412–2462 MHz •WLAN 5 GHz: 5150-5250 MHz Note that frequency band 5150-5250 MHz is for indoor use only, see national regulations. RF output (EIRP) • Bluetooth + EDR: <10 dBm •WLAN: <17 dBm Antenna •Integrated PIFA antenna (gain: maximum 2.6 dBi)

  • Video Out

    HDMI, DVI

  • Storage Media

    Removable SD card

  • Image File Format

    Standard JPEG, measurement data included. Infrared-only mode

  • Communication Interfaces

    USB 2.0, Bluetooth via headset, Wi-Fi, HDMI

  • Annotations

    Voice: 60 seconds with Bluetooth on still images and video Text: Text from predefined list or soft keyboard on touchscreen Image Sketch: Yes, on infrared only

  • Laser Pointer

    Class 2

  • Cloud Services

    Via Wi-Fi; FLIR Ignite for direct, secure image uploading, organizing, storage, and sharing (required firmware available)

  • Packaging Size

    400 × 190 × 510 mm (15.7 × 7.5 × 20.1 in)

  • GPS [removable]

    Location data automatically added to every still image and first frame in video from built-in GPS

  • Package Includes

    Infrared camera with lens, battery (2 pcs), battery charger, power supply including multi-plugs, hand strap, neck strap, lens cap, lens cap strap, memory card, HDMI-HDMI cable, USB cable, screwdriver TX20, knob screw (optional screw for the rear cover), printed documentation, hard transport case

  • FLIR Inspection Route

    Enabled in the camera

  • Size [L x W x H ] w Lens

    251.6 mm × 164.5 mm × 170.9 mm (9.9 in × 6.48 in × 6.73 in)

  • Weight [incl lens & batteries]

    3 kg (6.18 lb)

  • Languages

    21

  • Battery type

    Rechargeable Li-ion battery; 7.4 V, charged in camera or separate 2-bay charger

  • Charging Time

    2.5 hours to 95% capacity, charging status indicated by LEDs

  • Start Up Time

    Typically 7 min. at 25°C (77°F)

  • Battery operating time

    >2.5 hours at 25°C (68°F) and typical use

  • Mounting

    UNC 1/4"-20

  • Encapsulation

    IP54 (IEC 60529)

  • Certifications

    RoHS: 2011/65/EU WEEE: 2012/19/EU RED: 2014/53/EU EMC: ETSI EN 301 489-1 (radio), ETSI EN 301 489-17, EN 55032 (emission), EN 55035 (immunity), EN 61000-4-8 Level 5 (magnetic field), EN 61000-6-2, Immunity Industrial Environment, FCC 47 CFR part 15 B, class B (emission), ICES-003

  • Shock & Vibration

    Shock: 25 g (IEC 60068-2-27); Vibration: 2 g (IEC 60068-2-6)

  • Storage Temperature Range

    –30°C to 60°C (–22°F to 140°F)

  • Operating Temperature Range

    –20°C to 40°C (–4°F to 104°F)

For Sales & Support