The FLIR EM54 is ideal for inspecting and troubleshooting HVAC/R ducting systems within residential, commercial, and industrial facilities. This meter can help you verify that duct inlets and outlets have the specified volumetric flow – a prerequisite to an efficient functional system. Featuring humidity, wet bulb, and dew point functions, the EM54 can measure deviations from proper relative humidity levels. Plus, the included Type-K contact temperature probe is useful to check electric motors and thermal equipment components for proper operating temperatures.

GET QUOTE

EASY TO USE

Intuitively operate this simple, ergonomic meter with a backlit display, a ‘hold’ function that freezes readings, and well-marked function keys.

ACCURATE AND RELIABLE

Receive high-quality data consistently, and work without interruption. Using the tripod, place the meter away from objects that may influence relative humidity measurements.

INSPECT AND TROUBLESHOOT EFFICIENTLY

Work on a wide range of systems more efficiently using the contact temperature probe and wet bulb/dew point calculations.


Specifications

  • Air Flow

    0 to 999900 CMM (0 to 999900 CFM)

  • Dew Point

    -30 to 60°C (-22 to 140°F), ±3°C (4.8°F)

  • Air Temperature

    10 to 30°C (50 to 86°F), ±1°C (1.8°F); -30 to 9.9°C (-22 to 50°F) and 31 to 60°C (88 to 140°F), ±2°C (3.6°F)

  • Relative Humidity

    5% to 98% ±3.5%

  • Wet Bulb (Calculated)

    -30 to 50°C (-22 to 122°F), ±3°C (4.8°F)

  • Air Velocity (Vane Anemometer Probe)

    0.4 to 30 m/s, ±3% +0.2 m/s ; 79 to 5906 ft/min, ±3% +40 ft/min; 1.4 to 108 km/h, ±3% +0.8 km/h; 0.9 to 67.2 mph, ±3% +0.4 mph; 0.8 to 58.3 knots, ±3% +0.4 knots

  • Dew Point

    -30 to 60°C (-22 to 140°F), ±3°C (4.8°F)

  • Air Temperature

    10 to 30°C (50 to 86°F), ±1°C (1.8°F); -30 to 9.9°C (-22 to 50°F) and 31 to 60°C (88 to 140°F), ±2°C (3.6°F)

  • Relative Humidity

    5% to 98% ±3.5%

  • Wet Bulb (Calculated)

    -30 to 50°C (-22 to 122°F), ±3°C (4.8°F)

  • Air Velocity (Vane Anemometer Probe)

    0.4 to 30 m/s, ±3% +0.2 m/s ; 79 to 5906 ft/min, ±3% +40 ft/min; 1.4 to 108 km/h, ±3% +0.8 km/h; 0.9 to 67.2 mph, ±3% +0.4 mph; 0.8 to 58.3 knots, ±3% +0.4 knots

  • Contact Temperature Type K thermocouple

    -99.9 to 99.9°C (-148 to 212°F), ±1.5% +1°C (1.8°F); 100 to 1372°C (212 to 2502°F), ±1.5% +2°C (3.6°F)

  • Display Type

    Backlit, multifunction LCD

  • Battery Life

    120 hours typical

  • Battery Type

    1x 9 V

  • Auto Power Off (APO)

    Configurable from 5 to 60 min in 8 increments

  • Battery status indicator

    Low battery indication

  • Weight

    283.9 g (10 oz) with battery installed, no external probes

  • Air Flow

    0 to 999900 CMM (0 to 999900 CFM)

  • Includes

    Vane anemometer probe, Type-K thermocouple probe, soft carrying pouch, 9 V battery, tripod mount

  • Housing material

    Impact-resistant plastic

  • Anemometer Body Length

    150 mm (5.9 in)

  • Dimensions (L x W x H)

    275 × 65 × 45 mm (10.8 × 2.6 × 1.8 in)

  • Anemometer Cable Length

    950 mm (37.4 in)

  • Anemometer Vane Diameter

    70 mm (2.8 in)

  • Warranty

    Limited 3 years

  • Drop test

    1 m (3.3 ft), not including removeable probes

  • Certifications

    CE, RCM

  • Operating Temperature

    0 to 50°C (32 to 122°F)

  • Storage Temperature Range

    -10 to 60°C (14 to 140°F)